S.I.C.E.S. S.R.L.

GC 315

MC 200 Neptune

DNV certified shore connection controller
for marine power management systems

Icon

18 Digital inputs

Icon

18 Digital outputs

Icon

7 Analogue inputs

Icon

2 Analogue outputs

Icon

AND/OR Control logics

Icon

Configurable event history log

Icon

16 Calendars

Icon

USB

Icon

RS232

Icon

RS485

Icon

PLC Control logics

Icon

Ethernet connection

Description

DNV certification and high reliability
MC200Neptune is the latest shore connection controller of SICES with the DNV certification based on the already successful mains supervising controller of MC200, with enhanced coating and sealing to resist harsh marine environment, which justifies in 5 years of warranty.

Shore connection control
MC200Neptune is managing shore connection of a ship during harbor operation. It’s been designed to synchronize all gensets simultaneously (controlled by GC600Neptune genset controllers) to the mains, with the soft transfer of the loads from the gensets to the mains, avoiding any blackout on the loads during the short time in parallel operation.
A ship usually uses the mains power supply only, without gensets long time in parallel, during the shore connection.

MC200Neptune automatically or manually controls the shore connection by Mains Circuit Breaker (MCB) and a connection of the bus to the load by Master Generator Circuit Breaker (MGCB).


Further details
Shore connection protection
MC200 Neptune performs a continuous check of the mains voltages, mains currents and mains frequency characteristics and in case of any anomaly, it opens the Mains Circuit Breaker (MCB) to protect loads from faulty mains and to start the generators to supply the loads (auto mains fail function).
When the mains returns back to normal limits, MC200 Neptune allows the gensets reverse synchronization to the mains, avoiding a blackout on the loads (“short time parallel”).

Power Management System
MC200 Neptune is the part of the power management system along with GC600 Neptune genset controllers, communicating by CAN bus and providing:
• full automatic start and synchronization of a genset when a trip or a pre-warning of a supplying gensets occurs
• load-dependent start & synchronization of gensets
• load dependent unloading & stop of gensets
• automatic or manual change of gensets’ priorities
• reduced total fuel consumption by GC600Neptune‘s power management or synchronized mains supply during a harbor operation (shore connection) by MC200 Neptune, the shore connection controller
• combined operation of shaft generators and AUX generators for the minimum fuel consumption
• bow thruster power reserve activation or trip of unnecessary load, depending on a site configuration
• support of Dynamic Positioning System by predefined I/O's control interface or by communication with Integrated Vessel Automation System
• support of multiple shore connections by multiple MC200 Neptune within the power management system

All-in-one controller to fit any application
The controller has been fully equipped from a factory, i.e. neither optional hardware card nor software module is needed to purchase. The MC200 Neptune even comes with five of predefined application multi-genset modes.

Ensuring power supply
There is available manual/emergency operation and manual power management, based on e.g. a hardware signal of the controller’s watchdog.

Easy to operate
MC200 Neptune is equipped by a large 4.3” color dimmable display of three preset color schemes with an option to hide unnecessary pages and the dimmable LED’s.

High measurement accuracy
MC200 Neptune uses 12 bit A/D converter resulting in very accurate measurement of electrical and analog values, with e.g. 1% of AC voltage measurement error or 0.3% of AC current measurement error.

A part of ship’s IAS
The USB, RS232, RS485 (insulated) and Ethernet communication interfaces provide full integration of GC600 Neptune and MC200 Neptune controllers to the Integrated Vessel Automation System.

Accomplishment of various site requests
MC200 Neptune comes with in-built set of powerful PLC functions to manage any special request of the site.

Free PC software tools of SICES
Configuration of MC200 Neptune can be either done by controller’s keyboard or by BoardPrg4 software tool. Similarly, any complex PLC diagram can be easily created with the SicesPlcEditor software. On the bridge, free SCADA software of SicesSupervisor3 covers monitoring and control of SICES controllers and also party Modbus instrument too.
All free to download at www.sices.eu
Communication

Rear view connections and dimensions

Certification

MC200 Neptune includes

> The centralization of the start/stop commands towards the generators
> An internal synchronizer with voltage, frequency and phase differences control
> The centralized management of active power setpoints for the generators, to allow the gradual transfer of the loads with a rate
> The centralized management of power factor setpoints for the generators, when operating in shore connection
> The loss of mains protections (interface protections), to isolate the generators from the mains in case of failure of the mains itself
> The LOAD SHEDDING function (trip off unnecessary load), with 4 available levels, to ensure an urgent operation of bow thruster and avoiding blackout at the same time
> An end-lines loads voltages regulation function (by varying the generators voltage at the beginning of the line)
> Taking advantage of the internal calendar clock (with rechargeable backup battery):
Periodical genset’s start-up with programmable rate, in order to verify their efficiency (this test can be done without loads, in parallel to the mains or in island mode by transferring the loads from the mains to the generators)
Periodical and “on-event” history logs
> Embedded alarm horn
> Multilanguage display (EN, IT, FR, PT, ES, RU)
> Supply voltage: 8…32 Vdc
> Power consumption: typic al less than 6W (stand-by controller switched on, LCD lamp switched off)
> Operating frequency: 50Hz or 60Hz
> 4.3” TFT color display with backlight
> Graphic display resolution: 480x272 pixel
> Graphic display dimensions: visible surface 95 x 54mm
> Operating temperature: -25 °C to + 60 °C
> Storage temperature: -30 °C to + 80°C
> Protection degree: IP65 (only with gasket correctly installed)
> Weight: 1100g
> Overall dimension: 244 (W) x 178 (H) x 83 (D)
> Panel cut-out: 218x159 mm (L x H)
> Compliant with DNVG-CG-0339
> Location class:
  • Temperature: D
  • Humidity: B
  • Vibrations: A
  • EMC: A
  • Enclosure: B
> Safety: built in conformity to EN61010-1
Mains/Bus voltages

L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
True RMS measure
Lx-N max. voltage < 300Vac cat. IV. Rated input voltage: 100/400V
Voltage input reading 50000V max. (with external voltage transformers)

System and auxillary currents

L1, L2, L3, N (*)
True RMS measure
Internal current transformers. Rated input current: 5Aac e 1Aac
(*) The fourth current measurement can be used for differential protection or for
power measurement on genset’s bus bars

Mains and bus bars frequency

Resolution = 0.1 Hz. Accuracy = ±50ppm, ±35ppm/°C (typical)

Supply voltage

Resolution = 0.1V

Calculated values

Active and reactive power, power factor, are available as total measure and also for each single phase. Power and currents maximum reached values are stored with date and time. Additional analogical measures related to the engine are available in case of engines with CANBUS J1939 interface.

Commercial datasheets

For more information

Compila i campi richiesti.
Compila i campi richiesti.
Compila i campi richiesti.
Compila i campi richiesti.
Compila i campi richiesti.
© 2023 S.I.C.E.S. Società Italiana Costruzioni Elettriche Sumirago S.R.L.
Via Molinello n. 8/B 21040 - JERAGO CON ORAGO (VA) | Tel. +39 0331212941 | Fax +39 0331216102
Codice Fiscale, Partita IVA e N. Iscrizione al Registro Imprese CCIAA di Varese 00587340126 R.E.A. CCIAA di Varese 142977 VAT Number IT00587340126 Capitale Sociale € 500.000 i.v.

Design & programming Graphic studio VLADO